Skip to content

Overview ​

Document Information

Version: v2.2 Updated: 2026-11-16

Feature Overview ​

ItemContent
Applicable RoleModel Provider and Model Consumer
Navigation PathOn-Prem > Overview
Page Route/powerone/overview
Managed ObjectConfiguration, status, and relationships on Overview

Beginner Explanation ​

The overview page is like the homepage of the On-Prem user console: the upper area tells you which models can be deployed and which accelerators are available; the middle area provides quick entrypoints for Online IDE and Runtime Instance; the lower area helps you confirm whether quota is sufficient and whether resources have consumption records.

Terms Quick Reference ​

TermDescription
SpecificationResource package that a job can request, such as CPU, memory, GPU model, and card count.
QuotaResource upper limit available to a tenant. Common dimensions include GPU, CPU, memory, and specifications.
AcceleratorGPU, NPU, or other AI computing device, displayed on the page by vendor and model.
  1. Go to On-Prem > Overview.
  2. Check Deployment Templates to confirm whether a deployable model exists.
  3. Check Accelerator Vendors to confirm the accelerator types the current resource pool supports.
  4. Use the Online IDE or Runtime Instances card to enter the creation flow.
  5. Check Specification Quota, Consumption Trend, and the resource usage panels to confirm whether the resources a job needs are available.

First-Time User Notes ​

Confirm that the task involves Configuration, status, and relationships on Overview, and then follow the recommended order. If fields or state differ from expectations, check prerequisites before continuing downstream.

Prerequisites ​

  1. The current account can enter the AI Infra(On-Prem) subsystem.
  2. The operator has opened visible regions, availability zones, clusters, specifications, and templates for the tenant.
  3. To create an online IDE, runtime instance, or model instance, the account needs the corresponding creation permissions and available quota.

Page Description ​

Use this page to review deployment templates, accelerator resources, quick entries, specification quotas, and resource-usage trends.

In the current Model Consumer main view, the visible inputs are model search, the This Month / This Week period switch, and a date range. No Region or Resource Type selector is shown in this view. Verify region ownership on the corresponding source page rather than selecting a region here.

Overview

The upper area displays deployment templates and accelerator vendors; the middle area provides two quick entry cards for Online IDE and Runtime Instances; the lower area displays the specification quota table, the consumption trend chart, and the resource usage panels. The image below is a full-height capture of the page content area and does not include the fixed left menu.

Page Areas ​

Field/AreaDescription
Deployment TemplatesDisplays deployable models and deployment entrypoints. The deployment button is usually unavailable before a model is selected.
Accelerator VendorsDisplays accelerator models and adaptation status per vendor. This capture shows Huawei and NVIDIA; the Chinese capture shows NVIDIA only, and the earlier capture also showed AMD and Intel.
Quick Entry CardsThe two cards titled Online IDE and Runtime Instances each provide a Create Job entrypoint. The page itself shows no Quick Guide heading.
Specification QuotaDisplays the specification-level Specification, Quota, and Used columns.
Consumption TrendDisplays the consumption trend for the current cycle, with the This Month and This Week switch and a date range. If there is no job consumption, it shows an empty state.
Resource UsageDisplays the AI Accelerator, CPU, Memory, Online IDE, and Runtime Instances panels with their total and used values.

Main Operations ​

This section is organized by page area.

View Deployable Models ​

Applicable Scenarios ​

Use the Deployment Templates area to confirm which models the current tenant can deploy and to reach the deployment entry.

Steps ​

  1. Go to On-Prem > Overview.
  2. In the Model Vendors list, check the vendor row and its counters, for example the qwen row shows 1 deployable · 1 cards and 1 models.
  3. Expand a vendor row to read the model rows. A model row gives the parameter tags and the status, for example qwen3.5-0.8b with 0.8B, qwen, 262K, and the status Deployable.
  4. Filter the list with the Search model / author / tag field, and restore the full list with Clear Filters.
  5. Click the > at the end of a model row to leave the overview and open the detail view of that model (the target page is outside this capture set). While no model is selected, the area title line shows Select a specific model before deployment and Deploy stays unclickable.

The image below is a close-up of the Deployment Templates area, so the vendor counters, model tags, status text, and deployment entry above can be aligned one by one.

Deployment Templates area: the Model Vendors list and the Deploy entry

Result Validation ​

  • The vendor row, the model rows, and the status text are all visible, and a deployable model reads Deployable.
  • After a keyword is typed in Search model / author / tag, the Model Vendors counter changes, and Clear Filters restores the full list.

Notes ​

  • Deploy appears disabled in this capture because no model is selected. The sibling Chinese capture shows the selected state, where the area title line names the chosen model and the button becomes clickable; the English wording of that label is not captured.
  • The vendor and model counts and the model list come from what the operator opened for this tenant, and neither the Model Provider nor the Model Consumer can change them on this page.
  • The Expand remaining 13 models row in the earlier capture does not exist in this capture set (this sample has 1 model in total), so do not write it from the old image.

Review Accelerator Vendors ​

Applicable Scenarios ​

Use the Accelerator Vendors area to confirm which accelerator types the current resource pool has adapted and whether a card model is managed.

Steps ​

  1. Read the adapted count at the right of the Accelerator Vendors title, for example 2 adapted accelerator types.
  2. In each vendor row, read the two counters, for example the Huawei row shows 1 managed and 0 unmanaged.
  3. Expand a vendor row to read the card rows. A card row gives the model, memory, and management status, for example Ascend 910B with 64GB and Managed, followed by the precision list BF16 · INT8 · FP16 and the peak throughput Peak 640 TFLOPS.

Result Validation ​

  • The adapted count and the vendor row counters are visible together, and each vendor arrow matches the collapsed or expanded state of that row.
  • The model, memory, and management status of a card row are readable within one row, with the precision list and peak throughput below it.

Notes ​

  • A collapsed vendor row (for example NVIDIA showing 1 managed and 0 unmanaged) gives counters only, and the card details appear after it is expanded.
  • Whether a card row offers an entry to its detail page is not confirmed in this capture set, so this section does not write that entry.
  • The earlier capture contains the AMD and Intel vendor rows, which are not visible in this capture set; the page area table records this as a version difference instead of deleting the row.

Create Jobs from the Quick Entry Cards ​

Applicable Scenarios ​

Use the two quick entry cards in the middle of the page to start the creation flow of an interactive development environment or a runtime instance directly from the overview page.

Steps ​

  1. Confirm the two cards in the middle of the page: the blue Online IDE card and the green Runtime Instances card, each with one description paragraph and one Create Job button.
  2. Click Create Job inside the Online IDE card to enter the creation flow of an online development environment.
  3. Click Create Job inside the Runtime Instances card to enter the creation flow of a runtime instance.

Result Validation ​

  • Both cards and their Create Job buttons are visible together, and the card titles match the Online IDE and Runtime Instances items of the left user menu word for word.
  • After the click, the page leaves the overview; the overview page itself shows no creation result.

Notes ​

  • The target form fields, required marks, and submit messages of both creation flows are outside this capture set, so this section does not write them.
  • The cards are entrypoints only, and they do not replace the pages under Model Deployment > Instances or Dev Resources.
  • Whether creation succeeds also depends on the quota and the remaining resources, so check the Specification Quota table and the usage panels on this page first.

Review Specification Quota and Consumption Trend ​

Applicable Scenarios ​

Use the Specification Quota table and the Consumption Trend chart in the lower half of the page to confirm the upper limit and used amount of each specification and the consumption curve of the current cycle.

Steps ​

  1. Read the three columns of the Specification Quota table: Specification, Quota, and Used.
  2. Check the form of the quota value: no upper limit shows Unlimited, and a limited quota shows a number, for example 6 and 4.
  3. Check the form of the used value: no consumption record shows --, and a record with consumption shows a duration, for example 8h 20m 51s.
  4. Switch This Month and This Week at the right of Consumption Trend, and check the date range, for example 2026-09-01 - 2026-10-23; the vertical axis unit is Units, and the legend is given by specification name, for example nv-v100-32g-g1c12m24g.

The image below covers the specification quota and consumption trend band, so the three quota columns, the cycle switch, and the specification legend can be aligned one by one.

Specification Quota table and Consumption Trend chart: cycle switch, date range, and specification legend

Result Validation ​

  • After switching This Month and This Week, the date range follows the selected cycle, and each legend name maps to a specification row of the Specification Quota table.
  • The value forms of the Quota and Used columns stay consistent within one screen, and one column never mixes numbers with durations.

Notes ​

  • This capture shows a curve, while the bottom Units chart shows No resource consumption data; the empty-state wording of Consumption Trend itself is not captured. An empty trend does not mean the quota is 0, so verify it in Quotas & Usage > Usage.
  • This capture set shows no region or project selector in the upper-right corner, so whether the statistics scope can be switched by region is not confirmed.

Review Resource Usage Panels ​

Applicable Scenarios ​

Use the resource usage panels in the lower half of the page to confirm the total and used amount of accelerators, CPU, memory, and the two job types.

Steps ​

  1. In the AI Accelerator panel, check the usage value at the center of the ring, the Total Usage label, and the title line Total AI Accelerators: 5.
  2. In the detail table of the same panel, read the four columns Resource Name, Total, Unused, and Used, for example the other_gpus row shows 5 AI card(s), 5 AI card(s), and 0 AI card(s).
  3. In the CPU panel, check that Total reads Unlimited and Used reads 0vCPU.
  4. In the Memory panel, check that Total reads Unlimited and Used reads 0GiB.
  5. In the Online IDE and Runtime Instances panels, check Running Jobs / Total in each, which reads 0 / 0 in this capture set; the bottom of the panel area shows No resource consumption data.

Result Validation ​

  • The titles and values of all five panels are visible together, and the card unit of the AI Accelerator detail table is consistently AI card(s).
  • The ring value, the detail table, and the panel title give the same total for one resource, and the same resource never shows two different totals in different places.

Notes ​

  • The earlier capture titles this panel AI card with Total AI cards: Unlimited, while this capture shows AI Accelerator with Total AI Accelerators: 5. This is a version difference, and the text follows this capture.
  • The panels give summary values only; the detail of a single card or a single job must be verified in the pages under Monitoring.

Troubleshoot Quota or Resource Anomalies ​

Applicable Scenarios ​

When the deployment entry is unavailable, a target specification cannot be requested, or an instance fails scheduling after creation, locate the cause on this page first: a quota shortage or a resource shortage.

Steps ​

  1. Return to the Specification Quota table, record the target specification row with its Quota and Used values, and record the vendor and card model.
  2. Go to Quotas & Usage > Usage to verify the allocated quota and the consumption records of the current tenant or project.
  3. If the quota is sufficient but the instance still fails scheduling, check Monitoring > Overview, Clusters, Nodes, and Devices to verify whether the physical cards are fully occupied; the availability-zone entry and its values are outside this capture set.

Result Validation ​

  • The target specification row is locatable in the Specification Quota table, and its quota and used values map to the records in Quotas & Usage > Usage.
  • The accelerator usage value on the overview page and the device statistics under Monitoring show no directional contradiction within the same time range.

Notes ​

  • A sufficient quota does not mean the cluster definitely has idle resources. When creation fails, also check the availability zone and the specification.
  • Overview data may have statistical delays. For troubleshooting, verify again on the instance detail, monitoring, or quota pages instead of concluding from the summary on this page.
  • This page provides no quota adjustment entry. Quota changes are completed by the operator on the Operator side.

Parameter Quick Reference ​

Query and Filters ​

Query controls are grouped by their documented page area. Grouped rows are not new UI fields. An em dash means the column is unspecified; it does not establish backend requirements, types, or defaults.

Field NameRequiredField TypeExampleDescription
Period switch / date range———In the current Model Consumer main view, the visible inputs are model search, the This Month / This Week period switch, and a date range. No Region or Resource Type selector is shown in this view. Verify region ownership on the corresponding source page rather than selecting a region here.
Search model / author / tag———4. Filter the list with the Search model / author / tag field, and restore the full list with Clear Filters.

Existing Fields ​

Field NameRequiredField TypeExampleDescription
QuotaSystem-generatedNumberSample quotaAvailable quota for the current account.
Used AmountSystem-generatedNumberSample used amountCurrent used resource amount.
Update TimeSystem-generatedDate timeSample update timeOverview data update time.

Pitfalls ​

  • When the deployment button is unavailable, usually no model or accelerator has been selected.

  • Sufficient quota does not mean the cluster definitely has idle resources. If creation fails, check region, availability zone, and specifications.

  • Do not record real tenants, regions, clusters, specifications, resource usage, consumption data, or test parameters.

  • Overview data may have statistical delays. For troubleshooting, verify again on instance details, monitoring, or quota pages.

Result Validation ​

Check ItemSuccess SignalIf Abnormal
Page entryOverview opens with filters or statisticsCheck menu permission, current business identity, and tenant scope
Data scopeCheck the model-list keyword or the trend period and date range, as applicableVerify time boundaries and object identifiers; confirm region ownership on the corresponding source page
Data updateUpdate time or latest record matches the expected cycleCheck whether the source job, metering, or quota record has been generated
Cross-checkConfiguration, status, and relationships on Overview matches its details, billing, or monitoring recordsCompare the responsible detail page by object identifier and time range

FAQ ​

No Records on Overview ​

Symptom:

The page opens, but lists or statistics are empty.

Possible Causes:

  • Filters are too narrow.
  • source records are not generated.
  • the role cannot see them.

Solution:

  1. Reset filters
  2. verify the source job or metering cycle
  3. check business identity and tenant scope.

Overview Shows the Wrong Scope ​

Symptom:

Data does not belong to the expected time, region, or object.

Possible Causes:

  • Time boundaries differ.
  • the region filter did not apply.
  • ownership changed.

Solution:

  1. Check the trend period and date range; verify region ownership on the corresponding source page
  2. verify object identifiers
  3. confirm ownership in source details.

Overview Is Delayed ​

Symptom:

A source operation completed, but its record is not visible.

Possible Causes:

  • Aggregation is not complete.
  • the page is cached.
  • source state is still processing.

Solution:

  1. Verify source state
  2. wait one aggregation cycle and refresh
  3. inspect the processing task if delay persists.

Details or Download Is Unavailable ​

Symptom:

The details, expand, or download entry is disabled.

Possible Causes:

  • The record does not support it.
  • role permission is insufficient.
  • the file is not generated.

Solution:

  1. Select an eligible record
  2. check role permission
  3. confirm the statistics or export task is complete.

Summary and Details Do Not Match ​

Symptom:

The summary differs from the total of individual records.

Possible Causes:

  • Periods differ.
  • values are rounded.
  • some records are still processing.

Solution:

  1. Align period and time zone
  2. compare by object
  3. wait for pending records and check again.

Notes ​

  • Do not judge failure causes only by the homepage summary. Key instance status should be based on the corresponding detail page.
  • Before creation, confirm region, specification, and image source to avoid creation failure caused by unschedulable resources after submission.
  • The overview page only provides summary display and does not replace creation, detail, or troubleshooting pages of specific modules.
  • Templates, specifications, and accelerators are configured by operators. Model Consumers cannot modify them directly on the overview page.

Next Steps ​

  1. Go to Model Deployment > Templates to create a model instance.
  2. Go to Dev Resources > Online IDE to create an interactive development environment.
  3. Go to Quotas & Usage > Quotas to view resource limits.