Skip to content

Scenario Overview - On-Prem Resource Metering and Monitoring ​

This scenario explains how to grant NPU quota and inspect device, node, and workload usage. Check usage against the target device inventory and approved limits, then use individual instance records to investigate abnormalities.

Resource limits cap resource quantities. Specification quota is the available usage time in hours for a specification. Credits are platform accounting units, not a physical card count.

Example scope: The linked guides retain a four-NPU example. Use the actual hardware inventory, compatibility, and approved workload to determine model, count, and resource tiers; four cards or all one-/two-/four-card plans are not prerequisites for every environment.

Applicable Roles ​

  • Platform Operator
  • Provider and End User viewing their own usage

Role handoff: The Platform Operator maintains usage limits and reviews operator-level monitoring. Model Providers and users check their own quota, usage, and instance records. For operator assistance, provide the region, resource or task identifier, time, and billing cycle so monitoring and metering scopes can be aligned.

Goals ​

  • Grant an appropriate NPU quota to the tenant.
  • Check target accelerator recognition and monitoring data against the actual hardware inventory.
  • Correlate an abnormal card with its node and workload.

Scenario Flow ​

Main path: Configure tenant quota → Run workloads → Correlate devices, nodes, and jobs → Reconcile metering and adjust

StageKey Result
1. Configure quotaThe tenant receives an NPU limit that matches the plan
2. Run workloadsJobs request and occupy resources using the specifications actually required
3. Correlate monitoringAlign region, cluster, and object; use a common period where filters exist and record observation times for current snapshots
4. Reconcile and adjustKeep quota limits, actual allocation, and billing-cycle metering distinct, with traceable explanations for differences

Before You Start ​

  • NPU onboarding and monitoring collection are complete.
  • The tenant allocation policy is defined.
  • A test workload is available.
  1. Configure Tenant NPU Quota
  2. Monitor Devices, Nodes, and Workloads
  3. Reconcile Monthly Metering and Details
  4. Deploy and Check a Model

Document Index ​

DocumentDescription
Configure Tenant NPU QuotaGrant the tenant an allowed NPU count
Monitor Devices, Nodes, and WorkloadsVerify health and usage from device, node, and workload views
Reconcile Monthly Metering and DetailsMap tenant credits, monthly usage, and metering details to actual workloads

Completion Checklist ​

Confirm the results below before moving on; use the linked procedure to resolve failed checks.

CheckPass Criteria
1Tenant quota supports the intended workload.
2Target device recognition and available monitoring data have been checked against the hardware inventory.
3Workload usage, node capacity, and device utilization agree.
4Tenant credits, monthly usage, and metering details reconcile for the same billing cycle.